Pinouts (M12 & Terminal)
This page provides complete pinout details for the OV80i smart camera’s connectors, including the 12-pin M12 Power & I/O interface and the M12 X-coded Ethernet port.
M12 A-Coded 12-Pin – Power & I/O Connector
The OV80i uses a male M12 12-pin connector for power, digital I/O, and reset functionality.
Pin Layout
Pin | Signal Name | Function |
---|---|---|
1 | DI1 | NPN Active Low |
2 | Reserve | |
3 | Reserve | |
4 | Reset System BTN | |
5 | Digital Output 0 | NPN Active Low |
6 | Common In | |
7 | Power VIN (+24 VDC) | Primary power supply input |
8 | Power GND | 0V return path |
9 | DIO GND | |
10 | Trigger Input | NPN trigger or dry contact |
11 | DO0 | Output , NPN Sinking |
12 | DO1 | Output , NPN Sinking |
Pins 7 and 8 are required for powering the device.
M12 X-Coded Ethernet Connector
This 8-pin connector supports Gigabit Ethernet.
Pin | Signal | Function |
---|---|---|
1 | TD+ | Transmit Data (+) |
2 | RD+ | Receive Data (+) |
3 | TD– | Transmit Data (–) |
4 | RD– | Receive Data (–) |
5–8 | Bi-Directional | Gigabit pairs |
⚠️ Use an X-coded M12 Ethernet cable for connectivity.
Digital I/O Electrical Summary
Type | Logic | Trigger Method | Current Limit |
---|---|---|---|
Trigger Input | NPN-compatible | Pull to GND | – |
Digital Inputs | NPN-compatible | Pull to GND | – |
Digital Outputs | NPN Open Collector | Pulls to GND when active | 100 mA per line |
Always tie DIO GND (Pin 9) to your system or PLC ground.
Best Practices
- ✅ Use M12 screw-lock cables rated for industrial use
- ✅ Verify wiring polarity before powering up
- ✅ Add ferrules or strain reliefs in control panels
- ❌ Never hot-swap the M12 Power/I/O connector